HOME >>Analog Instruments Index >>Model :NRP NRC Seriese

Products

Analog Instrument

Meter Relay

Specification / Model
NRP-60H
NRP-60HL
NRP-83H
NRP-83HL
NRC-100H
NRC-100HL
NRC-120H
NRC-120HL
 
NRP-60
NRP-83H
NRC-100
NRC-120
Dimension
(mm)
60(W)×60(H)
-
-
-
83(W)×83(H)
-
-
-
100(W)×83(H)
-
-
-
120(W)×100(H)
-
-
-
Type Square
Input
(*)
DC Current (Moving coil)
500μA
1mA
10 - 100mA
100μA,500μA,1mA,10mA - 5A
DC Voltage (Moving coil)
1V - 300V
Receiver (Moving coil)
4 - 20mA, 1 - 5V(4kΩ), 1 - 5V(w / 1MΩ,7331)
AC Current (average)
1 - 20mA
1 - 300mA
(r.m.s., 1A or more)
1 - 5A(CT incorporated), 10 - 30A(w/7311)
AC Voltage (average)
10 - 300V
Indication Accuracy Class 1.5
-
Class 2.5
-
-
-
Scale length
46mm
67mm
88mm
Scale divisions 20 - 37.5
-
-
-
30 - 50
-
Scale Pointer
Needle type, black
Scale plate color
White
Cover color Black
7.5BG4 / 1.5
-
Output Optical operation
Output
Hold (relay)
Pointer
Knife shape H(High) : Red, L(Low): Green
Setting range
0 - 100% of scale for H and L
Setting
HL(High / Low) or H(High)
minimum setting range (per scale length)
5% or less
Pick up accuracy (per scale length)
1.5% or less
1.0% or less
Deadband (per scale length)
0.5% or less
Temp. coefficient
(pick up value at 23degree ±10degree)
0.3% or less
Power regulation
(pick up value at rated voltage ±10%)
0.3% or less
Output contact
1 transfer for H and L
Contact rate (load resistance)
250V, 2A a.c.
220V, 2A d.c.
250V, 3A a.c.
30V, 3A d.c.
Power on delay
-
100/110,200/220V AC
24V DC
Consumption
1.5VA or less
2.5VA or less
Operating temperature
0 - 50degree
Operating humidity
30 - 90%RH (no condensation)
Weight (1mA d.c. rated)
approx. 230g
approx. 530g
approx. 550g
approx. 600g

* The rated input to exceed the specified standard values is associated with an accessory.

●:Standard, ○:Option
page up