Digital Meter / Printer

Digital Integrating Flow rate Meter

MODEL 419A

  • ■ DIN 48x48 mm compact size
  • ■ Dual display of flow rate and totalizer
  • ■ Pulse output for total and 2 x preset output
  • ■ Analog input of 419A and pulse input of 419B can be linked in series

Operation manual

Model Designation

419A - - - -

①Measuring input

Code Measuring range Input impedance Over load
02 0 to 99.99 mV More than 1 MΩ DC ±250 V
03 0 to 999.9 mV More than 1 MΩ
04 0 to 5 V More than 1 MΩ
05 0 to 9.999 V More than 1 MΩ
09 1 to 5 V Approx. 1 MΩ
23 0 to 999.9 μA Approx. 100 Ω DC ±50 mA
29 4 to 20 mA Approx. 12 Ω DC ±150 mA
29R 4 to 20 mA Approx. 250 Ω DC ±40 mA

②Power supply voltage

Code Power source voltage
A AC 100 to 240 V
8 DC 12 V ±10%
9 DC 24 V ±10%

③Power source for sensor

Code Output voltage Output current Ripple
Blank Not available
3 12 V ±5% 60 mA Less than 5%
5 24 V ±5% 30 mA Less than 5%

④Analog output, RS-485

Code Output specifications Output impedance Tolerable Load resistive
Blank -
03 DC 0 to 1 V Approx. 0.1 MΩ More than 200 Ω
04 DC 0 to 5 V More than 1 kΩ
05 DC 0 to 10 V More than 2 kΩ
09 DC 1 to 5 V More than 1 kΩ
29 DC 4 to 20 mA 5 MΩ 0 to 500 Ω
E1 RS-485 -

Basic Specifications

Flow rate measurement
Flow indication 0 to 9999: Red LED, Character 8mm High, with zero-suppress function.
Programmable Decimal point Over-range display
Display blank Changeover to be put on or off.
Scaling Full scale and Offset, Programmable 0 – 9999
Resolution 1/9999
Display cycle Selectable from the front key. 100ms, 400ms, 1s, 2s, 5s
Moving averaging Selectable from the front key. 1, 2, 3, 4, 8, 16-time
Accuracy ±0.2% of SPAN at 23 ± 5°C  45 to 75% RH
Temperature drift ±200 ppm/°C
Input method Single ended, floating
A/D conversion V-F conversion method
Flow totalize measurement
Flow indication 0 to 99999: Green LED, Character 8mm High, with zero-suppress function.
5 or 10 significant digit: Over-range display:
Display blank: Changeover to be put on or off.
Integration constant Values integrated in 1 hour at 100% input, programmable from the front key.
Primary integrated value from 0 to 99999, programmable from the front key
Accuracy ±(0.2%+1digit) of rated value
Rated value: theoretical value when input 100% continuously.
Display cycle approx. 100ms
Common Specifications
Cut off 0 to 10%: Programmable from the front key.
Latch / Pause input Latch:
Hold display of instantaneous and integrating flow rate, and data output (except of Simultaneous pulse output). Accumulated integrated count will be operated.
Pause:
Hold display of instantaneous and integrating flow rate, and data output. Accumulated integrated count will be temporarily stopped.
Non-voltage contact or open collector (NPN) DC 5 V, 10 mA
Reset reset to 0 or primary setting value
Backup An EEPROM retains the data of accumulated total flow when the power is interrupted. Keep 10 years.
Output relay contact: AC/DC 150 V, 80 mA
Noise filter 50 dB at normal mode
110 dB at common mode
1000 V against the power line noises
Withstand Voltage Input terminals - External case: AC 1500 V each for 1min.
Power supply terminals - External case: AC 1500 V each for 1min.
Power supply terminals - Input and Output terminals: AC 1500 V each for 1min.
Input terminals - Output terminals: AC 500 V each for 1min.
Insulation Resistance DC 500 V, More than 100 MΩ
Power Supply AC 100 to 240 V (50/60 Hz), DC 12 V ±10%, DC 24 V ±10%
Allowable power AC 90 to 250 V (50/60 Hz), DC 10.8 to 13.2 V, DC 21.6 to 26.4 V
Power Consumption Approx. 7.5 VA at AC 100 V, 10 VA at AC 200 V, 400 mA at DC 12 V, 250 mA at DC 24 V.
Operating Temperature 0 to 50°C
Storage Temperature -20 to 70°C
Weight Approx. 160 g