Digital Meter
AC Input Scaling Meter
MODEL 3195
- ■ Compact design of 48 x 24 mm, RMS value type
- ■ Scaling function and zero supress fucntion are equipped.
- ■ Max. display 9999
Standard Specifications
Model Designation
| 3195 | - | □ | - | □ |
| ① | ② |
①Measuring Input
| Code | Measuring Range | Input Resistance | Accuracy *1 | Overload *3 |
|---|---|---|---|---|
| 23 | 999.9 mV rms | 1 MΩ | ±(0.2% of rdg. + 10 digit) | AC 100 V |
| 24 | 9.999 V rms | 1 MΩ | AC 200 V | |
| 25 | 99.99 V rms | 10 MΩ | AC 250 V | |
| 26 | 300.0 V rms | 10 MΩ | AC 300 V | |
| 35 | 99.99 mA rms | 1 Ω | ±(0.3% of rdg. + 10 digit) | AC 500 mA |
| 36 | 999.9 mA rms | 0.1 Ω *2 | ±(0.5% of rdg. + 10 digit) | AC 2 A |
| 37 | 2.000 A rms |
- *1 Accuracy:
- Defined at 23 ± 5°C, 45 to 75% RH.
Defined with sine wave of input frequency 40 Hz to 1 kHz, and at 4% or more of the rated input. - *2
- External shunt resistor 0.1 Ω
- Temperature coefficient:
- ± 300 ppm/°C. Defined over an operating temperature range of 0 to 50°C
- Crest factor:
- 4 (peak 500 V for -26, peak 3 A for -36 and -37)
- *3 Overload (1min):
- Applying a voltage or current that exceeds the excessive input range to the input may damage the equipment.
- Note:
- The display will show 0, when the input is less than 0.1%of the rated input.
②Display Color
| Code | Content |
|---|---|
| R | Red LED |
| G | Green LED |
General Specifications
| Display | 000 to 9999 Red or green LED (character height 10 mm) with zero suppression function |
|---|---|
| Scaling function | Full scale display: 0 to 9999 Offset display: 0 to 9999 |
| Offset fixing function | Function of fixing display value to offset value when input is less than offset value. |
| 100 digit fixed to 0 | Setting is possible. |
| Decimal point display | Setting is possible from the front panel. |
| Over-range display | Flashing with 115% display.(But when exceeded 9999, flashing is displayed by 0000.) |
| Resolution | 1/10000 |
| Sampling rate | 1 time/sec. |
| Display cycle | 1s |
| Input configuration | Single ended |
| A/D conversion | Δ-Σ conversion system |
| Insulation resistance | DC 500 V than 100 MΩ or more |
| Withstand voltage | Between input terminal and outer case: AC 500 V 1minute Between power supply terminal and outer case: AC 500 V 1minute Between power supply terminal and input terminal: AC 500 V 1minute |
| Power supply | DC 12 to 24 V |
| Power supply voltage tolerance | DC 10.8 to 32 V |
| Power consumption | DC 12 V Approx. 50 mA DC 24 V Approx. 30 mA |
| Operating ambient temperature | 0 to 50°C |
| Storage temperature | -20 to 70°C |
| Weight | Approx. 45 g |