Our Technology, solution for Tomorrow too!

Digital Meter / Printer

Digital Large Waterproof Display Meter

MODEL 4025,4026

  • ■ Smart design
  • ■ Safe waterproof type. (IP65)
  • ■ 56mm clear large size LED display with high brightness.
  • ■ Wall or hanging-mount available.

Operation manual

Model Designation

402 - - - - -
 

①Measuring input

Code Measuring range (Type of input) Display range / Input resistance Accuracy*1
5-02 -200 to 999°C (K) -270 to 999°C ±(0.3% of rdg. + 1°C)
5-04 -40 to 750°C (J) -210 to 999°C
5-05 -200 to 350°C (T) -270 to 420°C
5-11 -200 to 850°C (PT100Ω) -200 to 870°C ±(0.4% of rdg. + 1°C)
5-12 -99.9 to 99.9°C (PT100Ω) -99.9 to 99.9°C ±(0.2% of rdg. + 0.3°C)
6-03 ±999 mV (DC V) 1 MΩ ±(0.1% of rdg. + 1digit)
6-04 ±9.99 V (DC V)
6-09 1 to 5 V ±(0.1% of rdg. + 2digit)
6-19 4 to 20 mA 12.5 Ω
*1 Accuracy:
Defined at 23°C ± 5 °C, 45 to 75 %RH
Temperature coefficient:
± 300 ppm/°C (K,J,T), ± 200 ppm/°C (Pt), ± 100 ppm/°C (-03), ± 150 ppm/°C (-04, -09, -19)
Operating temperature range:
-10 to 50 °C
Overload:
DC ± 10 V (K,J,T,Pt), DC ± 250 V (-03, -04, -09), DC ± 150 mA (-19)
Calibration:
JIS C-1602-2015 standard thermoelectric power mV (K,J,T)
JIS C-1604-2013 standard resistance element resistance values (Pt)

②Power supply

Code Content
A AC 100 to 240 V
9 DC 24 V

③Mounting method / Sensor (only for RTD input)

Code Mounting method Sensor Protection rate
51 Wall-hanging Sensor not included IP55 equivalent
52 Suspending
53 Wall surface mounting IP65 equivalent
61* Wall-hanging Integrated sensor type IP55 equivalent
62* Suspending
63* Wall surface mounting IP65 equivalent

*Integrated sensor type (PT100Ω input type only)

④Display color

Code Function
R Red LED
G Green LED

⑤Optional Function

Code Function
X Peak hold
A01 Bottom hold
A02 Burnout (min. value flashes) *

*Sensors of K,J,T only

Basic Specifications

Protection rate Wall-hanging and suspending installation: IP55 equivalent
Wall surface mounting installation: IP65 equivalent
Display 3-digit LED 56 mm height, red or green colors with zero-suppression function.
Scaling Function Full scale display: -19999 to +19999 (with full scale display setting function)
Offset display: -19999 to +19999 (with offset display setting function)
Adjustment: Display value can be adjusted.
Polarity display (POL) " - " is displayed.
Over-range display Temperature input: Min. or Max. value of display range flashes.
DC input: Value of 130% of display range flashes. But 000 flahes, when it exceeds 999.
Decimal point Temperature input: Fixed point
DC input: Arbitrary setting
Burnout Max. value of display range flashes. (only for temperature input)
Resolution Temperature input: 1 ℃ or 0.1 ℃
DC input: 1/1000
External resistance Thermocouple input: less than 500 Ω
RTD input: Lead wire line less than 5 Ω
Display cycle Temperature input: approx. 5-time/s.
DC input approx. 15-time/s.
Input configuration Single-ended, floating input
A/D conversion Δ-∑ conversion system
Noise reduction rate Normal mode (NMR) : more than 50 dB
Common mode (CMR): more than 110 dB
Power line mixed noise: 1000 V
Insulation Resistance DC 500V 50 MΩ or more
Withstand Voltage Between input terminal and external case: AC 1500 V 1min.
Between power supply terminal and external case: AC 1500 V 1min.
Between power supply terminal and input terminal: AC 1500 V 1min.
(DC power supply model AC 500 V 1min.)
Power Supply AC 100 to 240 V (50/60 Hz), DC 24 V
Power supply voltage tolerance AC 85 to 250 V, DC 20 to 30 V
Power Consumption AC 100 V approx. 6 VA
AC 200 V approx. 9 VA
DC 24 V approx. 100 mA
Operating ambient Temperature -10 to 50°C
Storage Temperature -20 to 70°C
Weight Approx. 1.5 kg
Unit display Attached on front panel. (Required unit can be attched for 4026, please specify at the order.)

page top