Our Technology, solution for Tomorrow too!

Digital Meter

Thermocpouple, Resistance Thermometer

MODEL 418M

  • ■ Front panel IP 65 protection
  • ■ DIN 72×36mm compact size
  • ■ Applicable to various temperature sensors

Operation manual

Standard Specifications

Model Designation

418M - - -

①Input Specification

Thermocouple (T/C)
Code Temperature sensor *1 Measuring range Display range Accuracy *2
TC R 0 to 1600 °C -50 to 1750 °C ±(0.3% of rdg. +1°C)
K -199 to 1200 °C -199 to 1350 °C
E -199 to 800 °C -199 to 1050 °C
J -40 to 750 °C -199 to 1250 °C
T -199 to 350 °C -199 to 420 °C
B 600 to 1700 °C -20 to 1810 °C
N -40 to 1200 °C -199 to 1350 °C
*1:
K Thermocpouple is set as initial factory shipment
*2 Accuracy:
Specified at measuring range
Defined at 23°C ± 5°C, 45 to 75% RH,
Temperature coefficient:
± 300 ppm/°C. Defined over an operating temperature range of 0 to 50°C
Reference junction compensation:
± 1 °C for operating temperature range 0 to 50 °C

Calibrated according to JIS C-1602-2015 standard thermoelectric power mV input

Resistance Temperature Detector (RTD)
Code Temperature sensor *3 Measuring range Display range Accuracy *4
PT PT 100 Ω -199.9 to 850.0 °C -199.9 to 870.0 °C ±(0.2% of rdg. + 0.3°C)
JPt 100 Ω -199 to 600 °C -199 to 650.0 °C
*3:
Pt 100Ω is set as initial factory shipment
*4 Accuracy:
Specified at measuring range
Defined at 23°C ± 5°C, 45 to 75% RH,
Temperature coefficient:
± 200 ppm/°C for 0 to 50 °C

Calibrated according to JIS C-1604-2013 standard resistance element resistance values

②Power Supply

Code Content
A AC 100 to 240 V
B DC 12 to 24 V

③Data output / Comaprison output

Code Specifications Output Impedance Allowable Load Resistance
X No output
03 Analog output DC 0 to 1V Less than 0.1 Ω More than 1 kΩ
04 Analog output DC 0 to 5 V Less than 0.1 Ω  More than 5 kΩ
05 Analog output DC 0 to 10 V Less than 0.1 Ω More than 10 kΩ
09 Analog output DC 1 to 5 V Less than 0.1 Ω  More than 5 kΩ
23 Analog output DC 0 to 1mA More than 5M Ω 0 to 5 kΩ
29 Analog output DC 4 to 20 mA More than 5 MΩ 0 to 600 Ω
BP BCD output (TTL level, positive logic)  
BN BCD output (TTL level, negative logic)
DN BCD output (transistor output, sink type)
RY 2-point comparison (relay contact output)
TN 2-point comparison (open collector output NPN)
TP 2-point comparison (open collector output PNP)

General Specifications

Display Red LED (character height 15 mm) with zero suppression function
Mode display 1 digit, red LED (character height 8mm)
Over-range display When exceeding display range, displays minimum or maximum value flashing.
Open circuit of input Thermocouple input: Displays minimum value of display range flashing.
RTD input: Displays maximum value of display range flashing
Resolution Thermocouple input: 1 °C
RTD input: 1 °C or 0.1 °C
External resistance Thermocouple input: less than 500 Ω
RTD input: Lead wire 1 line less than 5 Ω
Overload DC ± 10 V
Sampling cycle 2.5 times/sec.
Input configuration Single-ended, floating input
A/D conversion Δ-Σ conversion system
Noise rejection Normal mode (NMR): 50 dB or more
Common mode (CMR): 110 dB or more
Power line input noise: AC power 1000 V, DC power 500 V
Hold function Measurement data, peak/bottom memory values and outpu data are kept.(Input is not isolated)
Peak memory/Bottom memory function Display of maximum value or minimum value are possible.(Switchable from the front panel)
Withstand voltage Between input terminal and output terminal: AC 500 V 1minute
Between input and output terminal and power terminal: AC 1500 V 1 minute (*)
Between power terminal and outer case: AC 1500 V 1minute
(* DC power supply: AC 500 V 1 minute)
Insulation resistance DC 500 V 100 MΩ or more
Power supply voltage tolerance AC 90 to 250 V 50/60 Hz
DC 10.8 to 32 V
Power Consumption DC 12 V 32 mA
DC 24 V 20 mA
Operating ambient temperature 0 to 50 °C
Protection grade IP 65 equivalent
Weight Approx. 200 g